TGF11 Filler
TGF11 Tracer Gas Filler
Leak testing with tracer gas requires filling your test object. The TGF11 Tracer Gas Filler is a stand-alone instrument which allows for easy and reliable tracer gas filling and evacuating. It ensures that the entire test object is filled with tracer gas at the right time and at the right pressure. It also evacuates the tracer gas after the test avoiding contamination of the work area.
The new user interface allows easy, intuitive control of the instrument reducing operating errors. The filler has no moving parts, thus minimizing maintenance expense, and is well-suited for use in industrial serial production.
The TGF11 is an accessory to INFICON hydrogen and helium leak detectors, such as Sensistor Sentrac Hydrogen Leak Detector.
Benefits
- Ensured tracer gas filling in the entire test object
- Avoids background contamination
- Made for demanding industrial environments
- Dual port for filling and evacuating for short cycle times
- Minimal maintenance
- Easy set-up
Features
- Evacuates, fills and purges the test object
- Available in low pressure version (0.05 – 2 barg/ 0.7 – 29 psi) and standard version (0.3 – 10 barg /4.4 – 145 psi)
- Gross leak test prior to tracer gas filling
- Prop valve for optimized filling
- Uses a cost-effective venturi pump for gas evacuation – minimazing maintenance costs
Typical Applications
- Industry
- Automotive
- Aerospace
- Packaging
- RAC
- Medical
- Process
Part Number
TGF11 Tracer Gas Filler, standard pressure | |
---|---|
Part Number | Description |
590-558 | Tracer Gas Filler TGF11, standard pressure version (0.3 – 10 barg /4.4 – 145 PSIG) |
TGF11 Tracer Gas Filler, low pressure | |
---|---|
Part Number | Description |
590-559 | Tracer Gas Filler TGF11, low pressure version (0.05 – 2 barg/ 0.7 – 29 PSIG) |
Specifications
Type | TGF11 Tracer Gas Filler, standard pressure | TGF11 Tracer Gas Filler, low pressure | |
---|---|---|---|
Pressure | 0.3-10 barg (4.4-145 PSIG) | 0.05-2 barg (0.7-29 PSIG) | |
Tracer Gas pressure supply | 100 – 1100 kPa (1 – 11 barg, 14.5 -159.5 PSIG) | 100 – 400 kPa (1 – 4 barg, 14,5 -58 PSIG) | |
Supplies | |||
Connections | Push in fittings, OD 6,10,12 mm | Push in fittings, OD 6,10,12 mm | |
Power Supply | 100 – 240 VAC, 50/60 Hz, 2 A | 100 – 240 VAC, 50/60 Hz, 2 A | |
Compressed Air | 300 – 1000 kPa (3-10 barg /43.5-145 PSIG) | 300 – 1000 kPa (3-10 barg /43.5-145 PSIG) | |
Capacity* | |||
Evacuation Time | 0.8 s/l to -0.5 barg (-7.2 PSIG); 1.6 s/l to -0.7 barg (-10.1 PSIG); 2.5 s/l to -0.8 barg (-11.6 PSIG) | 0.8 s/l to -0.5 barg (-7.2 PSIG); 1.6 s/l to -0.7 barg (-10.1 PSIG); 2.5 s/l to -0.8 barg (-11.6 PSIG) | |
Maximum vacuum | -0.85 barg (-11.6 PSIG) (85% vacuum) | -0.85 barg (-11.6 PSIG) (85% vacuum) | |
Communication Interface | USB device RS232 PLC Input/Output Operator interface |
USB device RS232 PLC Input/Output Operator interface |
|
Ambient temperature range | 5°-45°C (41°-113°F) | 5°-45°C (41°-113°F) | |
Dimensions (W x H x D) | 305 x 160 x 284 mm (12 x 6.2 x 11.1 in.) |
305 x 160 x 284 mm (12 x 6.2 x 11.1 in.) |
|
Weight | 9.5 kg (19.8 lb.) | 9.5 kg (19.8 lb.) | |
*Please note: The capacity depends on the connection to the test object. |