your best partner for vacuum

Transpector® APX ALD Single Pressure

INFICON Transpector APX remains the market leading Residual Gas Analyzer (RGA) for semiconductor and display process monitoring. INFICON knows semiconductor and display customers have unique needs, and the latest revision of the Transpector APX allows for more flexibility to meet specific application requirements, while maintaining industry leading measurement speed and sensitivity. Transpector APX  is the ideal RGA process monitor for semiconductor processes such as ALD, CVD, PVD, and Etch.

The next generation Transpector APX ALD Single Pressure inlet system is designed to survive process chemistries prone to particle or coating generation like ALD or PECVD. This allows for continuous monitoring to capture data points at all critical process steps. In addition the inlet is temperature controlled for resistance to corrosive gases, essential for chamber clean endpoint monitoring applications.

BENEFITS

  • Application specific platform design for longest lifetime on your ALD or CVD process for the best wafer and panel protection and process optimization
  • ALD ready with measurement speeds of over 550 data points per second
  • Reduced fab footprint by 30% and easier installation due ne high performance pumping system
  • Temperature controlled inlet with INFICON proprietary coating for discrete pressure inlet that can withstand harsh corrosive chemistry
  • Automated calibration ensures long-term data reliability and accuracy for sensor to sensor and tool to tool chamber matching
  • Transpector APX becomes a powerful process monitoring and diagnostics tool when integrated with FabGuard® software and supported by INFICON world-class application experts

Specifications

100 AMU 200 AMU 300 AMU
Total Pressure Range 5E-7 – 1E-3 Torr

6.6E-7 – 1.3E-3 mbar

5E-7 – 1E-3 Torr

6.6E-7 – 1.3E-3 mbar

5E-7 – 1E-3 Torr

6.6E-7 – 1.3E-3 mbar

Detection Limit <10 ppb <25 ppb <50 ppb
Process Pressure Range 1E-8 Torr – 1.2 atm

1.3E-8 mbar – 1.2 atm

1E-8 Torr – 1.2 atm

1.3E-8 mbar – 1.2 atm

1E-8 Torr – 1.2 atm

1.3E-8 mbar – 1.2 atm

Sensitivity (Low Emission) >4.0E-6 amps/Torr

>3E-6 amps/mbar

>2.0E-6 amps/Torr

>1.5E-6 amps/mbar

>1.0E-6 amps/Torr

>7.6E-7 amps/mbar

Sensitivity (High Emission) >2.0E-5 amps/Torr

>1.5E-5 amps/mbar

>1.0E-5 amps/Torr

>7.6E-6 amps/mbar

>5.0E-6 amps/Torr

>3.8E-6 amps/mbar

Consumables

Part number Description
969-800-G1S APX CIS Tungsten Filament Kit GOLD
969-800-G2S APX CIS Coated Filament Kit GOLD
969-801-G1S APX CIS Tungsten Ion Source Kit GOLD
969-801-G2S APX CIS Tungsten Ion Source Kit with Anode Liner GOLD
969-801-G3S APX CIS Coated Ion Source Kit GOLD
969-801-G4S APX CIS Coated Ion Source Kit with Anode Liner GOLD
961-707-G1 Electron Multiplier Replacement Kit
923-418-G2 Replacement diaphragm kit for 2-stage pump
^