CDG100D2
INFICON Edge Capacitance Diaphragm Gauge is a highly accurate vacuum measurement instrument designed for harsh manufacturing environments. The proven temperature controlled, corrosion resistant, ultra-pure ceramic sensor provides superior span stability over many years paired with state-of-the-art zero stability. Edge comes with the INFICON patented unique sensor shield which protects the gauge from undesired process by-products. Advanced electronics offer a wide range of configurable signal conditioning for all applications and optional EtherCAT fieldbus interface. The innovative heating concept enables a cool to the touch surface and saves valuable tool space. INFICON Edge is the smallest vacuum measurement instrument of its kind.
Benefits
- Compact, saves valuable tool space
- Easy integration, EtherCAT, wide variety of full scales and flanges, standard with two set points
- Easy one push button or remote signal zero command, zero offset adjustable
- Diagnostic port for quick service and maintenance
- Two year warranty, longer life time with advanced heating concept and gauge protection
- No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications
- Compliance & standards: CE, EN, UL, SEMI, RoHS
Typical Applications
CVD, Etch, PVD and other semiconductor production processes
Part Number
Dimensions
Specifications
Type | 1000 … 500 Torr / mbar | 200 … 1 Torr / mbar | |
---|---|---|---|
Accuracy (1) | % of reading | 0.15 | 0.15 |
Temperature effect | |||
on zero | percent FS/°C | 0.0025 | 0.0025 |
on span | % of reading / °C | 0.02 | 0.02 |
Pressure, max. | kPa (absolute) | 400 | 260 |
Resolution | percent FS | 0.003 | 0.003 |
Lowest reading | percent FS | 0.01 | 0.01 |
Lowest suggested reading | percent FS | 0.05 | 0.05 |
Lowest suggested control pressure | percent FS | 0.5 | 0.5 |
Temperature | |||
Sensor | °C | 100 | 100 |
Operation (ambient) (5) | °C | +10 … +50 | +10 … +50 |
Bakeout at flange | °C | ≤110 | ≤110 |
Storage | °C | –20 … +65 | –40 … +65 |
Supply voltage | +14 … +30 VDC or ±15 V (±5%) | +14 … +30 VDC or ±15 V (±5%) | |
Power consumption | |||
During Heat up | W | ≤20 | 20 |
At operating temperature | W | ≤14 | ≤14 |
Output signal (analog) | V (dc) | 0 … +10 | 0 … +10 |
Response time (2) | ms | 30 | 30 |
Degree of protection | IP 40 | IP 40 | |
Standards | |||
CE conformity | EN 61000‑6‑2/-6-3, EN 61010 & RoHS | EN 61000‑6‑2/-6-3, EN 61010 & RoHS | |
ETL certification | UL 61010‑1, CSA 22.2 No.61010‑1 | UL 61010‑1, CSA 22.2 No.61010‑1 | |
SEMI compliance (5) | SEMI S2 | ||
Electrical connection | D-sub, 15 pole, male | D-sub, 15 pole, male | |
Setpoint | |||
Number of setpoints | 2 (SP1,SP2) | 2 (SP1,SP2) | |
Relay contact | V (dc) | ≤30 | ≤30 |
Hysteresis | percent FS | 1 | 1 |
Diagnostic port | |||
Protocol | RS232-C | RS232-C | |
Read | pressure, status, ID | pressure, status, ID | |
Set | set points, filter, zero adjust, factory reset, DC offset | set points, filter, zero adjust, factory reset, DC offset | |
Materials exposed to vacuum | Aluminum oxide ceramic (AI2O3), stainless steel (AISI 316L (4)) | Aluminum oxide ceramic (AI2O3), stainless steel (AISI 316L (4)) | |
Internal volume | |||
I. volume 1/2” tube | cm³ (in.³) | 4.2 (0.26) | 4.2 (0.26) |
I. volume DN 16 ISO KF | cm³ (in.³) | 4.2 (0.26) | 4.2 (0.26) |
I. volume DN 16 CF-R | cm³ (in.³) | 4.2 (0.26) | 4.2 (0.26) |
I. volume 8 VCR® | cm³ (in.³) | 4.2 (0.26) | 4.2 (0.26) |
Weight | |||
Weight 1/2” tube | g | 837 | 837 |
Weight DN 16 ISO KF | g | 852 | 852 |
Weight DN 16 CF-R | g | 875 | 875 |
Weight 8 VCR® | g | 897 | 897 |
EtherCAT | |||
Protocol EtherCAT | protocol specialized for EtherCAT | protocol specialized for EtherCAT | |
Communication standards | ETG.5003 Part 1 “Semiconductor Device Profile” ETG.5003 Part 2080 “Specific Device Profile: Vacuum Pressure Gauge” | ETG.5003 Part 1 “Semiconductor Device Profile” ETG.5003 Part 2080 “Specific Device Profile: Vacuum Pressure Gauge” | |
Data rate | Kbps | 100000 | 100000 |
Node address | Explicit Device Identification | Explicit Device Identification | |
Physical layer | 100BASE-Tx (IEEE 802.3) | 100BASE-Tx (IEEE 802.3) | |
Digital functions read | pressure, status, ID | pressure, status, ID | |
Digital functions set | set points, filter, zero adjust, reset, DC offset | set points, filter, zero adjust, reset, DC offset | |
Process data | Fixed PDO mapping and configurable PDO mapping | Fixed PDO mapping and configurable PDO mapping | |
Mailbox (CoE) | SDO requests, responses and information | SDO requests, responses and information | |
EtherCAT connector | RJ45, 8-pin (socket), IN and OUT | RJ45, 8-pin (socket), IN and OUT | |
Cable | shielded Ethernet CAT5e or higher | shielded Ethernet CAT5e or higher | |
Cable length | m (ft.) | ≤100 (330) | ≤100 (330) |
Connector for CDG (analog output, supply voltage, setpoints) | D-sub, 15 pin, male | D-sub, 15 pin, male |