LDS3000
Modular Leak Detector LDS3000
Compact Performance at the Highest Level. With the LDS3000 leak detector, INFICON is opening a new chapter in the success story of leak testing systems. The successor to the LDS2010 is setting new standards for accuracy, reproducibility of measurement results and speed of leak testing.
The LDS3000 is extremely compact. The small dimensions, 13 X 9.45 X 11.1 in. (330 X 240 X 280 mm), make it even easier to integrate it into leak testing systems. More importantly, the space requirements and installation expense have been reduced even further by dispensing with a 19″ control module and improving the cabling considerably. In addition, there is an optional touch screen for easy operation and an optional field bus connection.
Benefits
- MORE COMPACT AND EASIER TO INTEGRATE Optimizing space requirements and installation costs – that is the fine art of systems engineering. Small dimensions, a significantly more compact design and improved cabling are the LDS3000 leak detector’s answer to these challenges for leak testing systems. Its performance is not only better than its predecessor the LDS2010 leak detector, but is so much more compact in its design that integration into leak testing systems is easier and more flexible. In addition, there are individualized, custom configuration possibilities such as touch screen operation or connection to field bus systems, which are available as an option.
- COMMUNICATIVE DIVERSITY The LDS3000 leak detector includes a wide range of analog interfaces, as well as a variety of digital interfaces. RS232, RS485, USB and optional Profibus a variety of users’needs.
- HIGH RELIABILITY The LDS3000 leak detector provides both high throughput rates and great quality and reliability. Downtimes and frequent maintenance are a thing of the past. Calibration times of 20 seconds are especially fast, but are seldomly needed. Leak rates of up to 1 x 10-11 mbar l/s are detected in less than 1 second.
Features
- Compact design allows individualized, custom integration into leak detection systems
- Communicative diversity through a wide range of analog and digital interfaces
- Considerably improved cabling
- Fast, optimized response times with I·CAL
- LDS2010 compatibility mode
- The new, patented routine allows calibration of the LDS3000 leak detector within 20 seconds.
Typical Applications
- Airbag parts
- Evaporators, condensers, compressors
- Valves
- Brake lines, fuel lines
- Hydraulic components
- Engines
Part Number
LDS3000 | |
---|---|
Part Number | Description |
560-300 | LDS3000 Leak Detector (additionally 1 data cable and a I/O-Module or BM1000-Module needed) |
560-310 | I/O 1000 module |
560-315 | BM1000 Profibus module |
560-316 | BM1000 PROFINET IO module |
560-317 | BM1000 DeviceNet module |
560-318 | BM1000 Ethernet/IP module |
560-320 | CU1000 Control unit (additionall 1 data cable needed) |
560-332 | Data Cable 2 m |
560-335 | Data Cable 5 m |
560-340 | Data Cable 10 m |
Specifications
Type | LDS3000 | |
---|---|---|
Min. detectable leak rate for Helium “ULTRA”-Mode | mbar•L/s | <1E-11 |
Min. detectable leak rate for Helium “FINE”-Mode | mbar•L/s | <5E-11 |
Min. detectable leak rate for Helium “GROSS”-Mode | mbar•L/s | <1E-9 |
Min. detectable leak rate for Helium “Sniffer”-Mode | mbar•L/s | <1E-7 |
Measuring units | mbar•L/s, Pa•m³/s, Atm cm³, g/a, ppm | |
Max. inlet pressure “ULTRA”-Mode | mbar | 0.2 |
Max. inlet pressure “FINE”-Mode | mbar | 0.9 |
Max. inlet pressure “GROSS”-Mode | mbar | 18 |
Response time | s | <1 |
Digital inputs/outputs (if used with I/O-Modul) | 10 inputs/8 outputs | |
Control input | V | max. 35 (SPS compatibel) |
Ion Source | 2 yttrium/iridium long-life cathodes (3 years guarantee) | |
lin/log recorder output | V | 0-10 |
Serial interface | RS232, RS485, fieldbussystem | |
Dimensions (L x W x H) | mm | 330 x 240 x 280 |
Ambient temperature range | °C | 10 – 45 |
Vacuum connections | DN 16 KF, DN 25 KF | |
Vacuum connections | DN 16 KF, DN 25 KF |
Accessories
LDS3000 | |
---|---|
Part Number | Description |
14511 | Pump-Modul, D4B, AC-motor, 230V, 50/60Hz |
14520 | Sniffer valve |
14521 | Sniffer line, 3m |
14522 | Sniffer line, 5m |
14523 | Sniffer line, 10m |
560-319 | XL Sniffer Adapter |
560-320 | CU1000 Control unit (additionall 1 data cable needed) |
560-323 | Internal Helium Test Leak TL7 for LDS3000 |
560-324 | DIN Rail Power supply 24v, 10A |
560-330 | Membrane pump, 4-stages ( Recommendet to use with XL Sniffer Adapter) |
Spare Parts
LDS3000 | |
---|---|
Part Number | Description |
20004642 | Replacement Sniffer tip, 400 mm |
Brochures
Manuals
- Operating Manual LDS3000 EN
- Operating Manual LDS3000 DE
- Interface Description LDS3000 EN
- Operating Manual BM1000 EN
- Operating Manual BM1000 DE
- Operating Manual CU1000 EN
- Operating Manual CU1000 DE
- Operating Manual IO1000 EN
- Operating Manual IO1000 DE
- Menu Structure LDS3000 EN
- Menu Structure LDS3000 DE
- Operating Manual XL Sniffer Adapter EN
- Operating Manual XL Sniffer Adapter DE
- Operating Manual LDS Retrofit Kit EN
- Operating Manual LDS Retrofit Kit DE
Catalogus
3D Step Files
Videos
LDS3000: How to Assemble the Leak Detector
LDS3000: How to Set the Display Limits
LDS3000: How to Do an Internal Calibration
LDS3000: How to Do an External Calibration
LDS3000: How to Set the Favorites
LDS3000: How to Use the Zero Function
LDS3000: How to Quickly Change the Horizontal Axis
LDS3000: How to switch to XL Sniffer Adapter Mode
LDS3000: How to change mass
LDS3000: How to update the software